You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
 
 
 

2.2 KiB

ROADMAP

Goal: a small, phone-first webpage that tells whether the laundry is done, based on the washing machine's power consumption.

Priority 1

Objective: show the laundry status from the last 3 one-minute power samples of the Tasmota plug.

Decided

  • Data source: MQTT topic tele/tasmota_washingmashine_C21183/SENSOR (Tasmota JSON, field ENERGY.Power in watts).
  • Broker: 192.168.1.11:1883, no credentials assumed. Address, port, topic and credentials (optional) are configurable via env vars.
  • Tasmota TelePeriod is 10 s, so the plug publishes about 6 messages per minute.
  • Architecture: small Go backend, packaged in Docker (Dockerfile plus docker-compose example), deployed by the user on their own server.
    • Subscribes to the broker over TCP and runs continuously, whether or not any page is open.
    • Sampling: it keeps the most recent ENERGY.Power message and records one sample per minute. A minute with no message received is recorded as a missing sample.
    • Keeps the last 3 samples in memory.
    • Serves the webpage and a JSON status endpoint (e.g. /api/status). Status is computed on the backend, so a page load shows the correct state at once.
    • HTTP port is configurable, default 8080.
    • The page re-fetches the status every 60 s.
  • Status rule (threshold 3 W, strictly below means idle):
Condition Message Color
fewer than 3 samples since backend start "Waiting for data..." grey
any of the last 3 samples is missing "Incomplete data" grey
all 3 samples under 3.00 W "Laundry done" default text color
otherwise (any sample 3.00 W or more) "Laundry not yet done" red
  • Page design:
    • White background, status text very large (the main element), readable on phones (responsive, viewport meta, no horizontal scroll).
    • Below the status, the last 3 power values in normal-size black text with a W suffix and 2 decimals (e.g. 47.70W). A missing sample is shown as --.
  • Access: home Wi-Fi only. No TLS or authentication in scope.
  • Language: English for UI text, code comments, logs, README.

Notes

  • State is in memory only. After a backend restart the page shows "Waiting for data..." until 3 samples are collected (about 3 minutes).